Skip to Main Content
  • McGraw Hill Medical
  • McGraw Hill Medical
    • Umbrella Logo Dropdown McGraw Hill Medical Home
    • Explorar m?s sitios
      AccessAnesthesiology
      AccessAPN
      AccessBiomedical Science
      AccessCardiology
      AccessDermatologyDxRx
      AccessEmergency Medicine
      AccessHemOnc
      AccessMedicina
      AccessMedicine
      AccessNeurology
      AccessObGyn
      AccessPediatrics
      AccessPharmacy
      AccessPhysiotherapy
      AccessSurgery
      Case Files Collection
      Clinical Sports Medicine Collection
      F.A. Davis AT Collection
      F.A. Davis PT Collection
      JAMAevidence
      Murtagh Collection
      OMMBID
      Pharmacotherapy Principles & Practice
  • Soporte técnico
    • Recursos para usuarios
    • ¿Quiénes somos?
    • Contáctenos
    • Enviar retroalimentación
  • Suscripciones
Iniciar sesión Sign In

Inicio de sesión MyAccess

Crear un perfil gratuito MyAccess
¿Olvidó su contraseña?
¿Olvidó su nombre de usuario?

Acerca de MyAccess

Si su institución se suscribe a este recurso y usted no tiene un perfil MyAccess, por favor póngase en contacto con el departamento de referencia de su biblioteca para obtener información sobre cómo acceder a este recurso desde fuera del campus.

Leer más
Inicie sesión mediante OpenAthens
Inicie sesión mediante Shibboleth
AccessMedicina home page Home
Navigation Menu Search Menu
  • Libros
  • Referencia rápida
    • Diagnosaurus®
    • Pruebas de diagnóstico
    • Guías
    • Calculadoras
    • 2 Minute Medicine®
    • Acrónimos
  • Fármacos
    • Monografías de fármacos
    • Interacción de fármacos
  • Multimedia
    • Animaciones 3D
    • Anatomía 3D - Módulos
    • Anatomía 3D - Desafío de anatomía
    • COVID-19
    • Harrison Podclass
    • Vídeos por aparatos y sistemas
    • Lecciones de farmacología
    • Harrison Animaciones de fisiopatología
    • Medicina de urgencias
  • Infografías
  • Casos
    • Casos
    • Casos de Microbiología
    • Desequilibrios hidroelectrolíticos/trastornos
    • Fisiopatología
    • Harrison Casos. Desafío visual
  • Autoevaluación
    • Por Recurso
    • Flashcards
  • Educación del paciente
     
    Acerca de búsqueda
    Enable Autosuggest
    ¡Bienvenido!

    Ha creado correctamente un Perfil de MyAccess para
    alertsuccessName.

    Las características de MyAccess incluyen:
    • Acceso remoto
    • Favoritos
    • Guardar figuras en PowerPoint
    • Descargar cuadros como archivos PDF
    Ir al Panel de control  Cerrar
    Inicio > 2 Minute Medicine® > Endocrinology >
    Book cover
    Editors and Contributors

    Bionic pancreas reduces glycated hemoglobin levels compared to semi-automated insulin-delivery systems

    by Grace Yin, Kiera Liblik
    +

    Originally published by 2 Minute Medicine® (view original article). Reused on AccessMedicine with permission.

    +

    1. Amongst patients with type 1 diabetes (T1D), a bionic pancreas caused a reduction in glycated hemoglobin levels over a 13-week period.

    +

    2. In comparison to the bionic pancreas group, semi-automated insulin delivery systems did not change glycated hemoglobin levels amongst patients with T1D.

    +

    Evidence Rating Level: 1 (Excellent)

    Study Rundown:

    +
    +

    T1D is an autoimmune disease that results in the destruction of insulin-producing cells in the pancreas, leading to persistently high levels of sugar in the blood and an inability of body tissues to use them. If uncontrolled, T1D can cause significant damage to arteries and nerves, even posing a risk of death. As such, maintaining good control of blood sugars is a key priority for persons with T1D. Towards this end, partially automated insulin-delivery systems have grown in popularity over the past decade. These typically describe methods of regulating blood sugars through continuous monitoring of blood glucose levels in combination with calculations of basal rates, carbohydrate intakes, and additional metrics involved in initiation. A newer system of insulin delivery, the iLet bionic pancreas, is a fully automated means of insulin delivery that bypasses several elements of the partially automated insulin delivery systems. The current study was a randomized trial comparing semi-automated insulin delivery systems against the iLet bionic pancreas amongst adults and children with T1D. The primary goal was to investigate the difference in change in glycated hemoglobin levels within the blood after 13 weeks of use. At the last follow-up, the bionic pancreas was able to reduce glycated hemoglobin levels amongst its users without causing significantly different rates of hypoglycemic episodes. In comparison, semi-automated insulin delivery systems did not result in a significant reduction in glycated hemoglobin levels. Further studies with longer follow-up and detailed assessments of whether the bionic pancreas can reduce the risk of hypoglycemia, hyperglycemia, and ketosis will be helpful in better understanding its potential for widespread use.

    +

    Click to read the study in NEJM

    In-Depth [randomized controlled trial]:

    +
    +

    The current study was a parallel group, unblinded, multicenter, randomized trial comparing the iLet bionic pancreas against semi-automated insulin delivery systems amongst persons aged 6-79 years old with T1D. Standard care was determined to be any method of insulin delivery that utilized unblinded continuous glucose monitoring tools. Participants (n=219) were randomly assigned to the iLet bionic pancreas group or the standard care group in a 2:1 ratio. The primary endpoint was a change in glycated hemoglobin levels at 13 weeks of follow-up. Secondary endpoints included percentage of time glucose levels were in pre-determined ranges (i.e., <54mg/dL, <70mg/dL, 70-180mg/dL, >180mg/dL, and >250mg/dL), and safety outcomes such as diabetic ketoacidosis, and episodes of severe hypoglycemia. At 13 weeks, the bionic pancreas reduced glycated hemoglobin levels in comparison to standard care (-0.5 percentage points; 95% Confidence Interval [CI], -0.6 to -0.3). The bionic pancreas group and standard care group did not show significant differences in the percentage of time that glucose was below 54mg/dL as measured through real-time continuous glucose monitoring (0.0 percentage points; 95% CI, -0.1 to 0.0). Notably, the bionic pancreas group reported 214 episodes of hyperglycemia (primarily due to infusion-set failure) compared to two in the standard-care group. However, neither group reported any episodes of diabetic ketoacidosis. Although further investigations into the safety profile of the bionic pancreas in comparison to standard care are needed, this study provided evidence of the potential of the bionic pancreas to enhance glucose control amongst persons with T1D.

    +

    ©2022 2 Minute Medicine, Inc. All rights reserved. No works may be reproduced without expressed written consent from 2 Minute Medicine, Inc. Inquire about licensing here. No article should be construed as medical advice and is not intended as such by the authors or by 2 Minute Medicine, Inc.

    Pop-up div Successfully Displayed

    This div only appears when the trigger link is hovered over. Otherwise it is hidden from view.

    Please Wait

    2MM Topics
    Cardiology
    Chronic Disease
    Endocrinology
    Gastroenterology

    AccessMedicina

    • Libros
    • Referencia rápida
    • Diagnosaurus®
    • Pruebas de diagnóstico
    • Guías
    • Calculadoras
    • 2 Minute Medicine®
    • Acrónimos
    • Fármacos
    • Monografías de fármacos
    • Interacción de fármacos
    • Multimedia
    • Animaciones 3D
    • Anatomía 3D - Módulos
    • Anatomía 3D - Desafío de anatomía
    • COVID-19
    • Harrison Podclass
    • Vídeos por aparatos y sistemas
    • Lecciones de farmacología
    • Harrison Animaciones de fisiopatología
    • Medicina de urgencias
    • Infografías
    • Casos
    • Casos
    • Casos de Microbiología
    • Desequilibrios hidroelectrolíticos/trastornos
    • Fisiopatología
    • Harrison Casos. Desafío visual
    • Autoevaluación
    • Por Recurso
    • Flashcards
    • Educación del paciente
    • Acerca de

    McGraw Hill Medical

    • Sites
    • AccessAnesthesiology
    • AccessAPN
    • AccessBiomedical Science
    • AccessCardiology
    • AccessDermatologyDxRx
    • AccessEmergency Medicine
    • AccessHemOnc
    • AccessMedicina
    • AccessMedicine
    • AccessNeurology
    • AccessObGyn
    • AccessPediatrics
    • AccessPharmacy
    • AccessPhysiotherapy
    • AccessSurgery
    • Case Files Collection
    • Clinical Sports Medicine Collection
    • F.A. Davis AT Collection
    • F.A. Davis PT Collection
    • JAMAevidence
    • Murtagh Collection
    • OMMBID
    • Pharmacotherapy Principles & Practice
    • Soporte técnico
    • Recursos para usarios
    • ¿Quiénes somos?
    • Contáctenos
    • Enviar retroalimentación
    • Suscripciones
    • Suscripciones Institucionales
    • Suscripciones individuales
    McGraw Hill

    Copyright © McGraw Hill
    Todos los derechos reservados.
    Su dirección IP es 34.239.152.207
    Términos de uso   •  Aviso de privacidad   •  Anuncio   •  Soporte de Navegador

    Silverchair
    Arriba
    >
    Este sitio usa cookies. Al continuar navegando en este sitio, usted acepta nuestro uso de cookies. Más información Cerrar